Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply

Short Description:

Product parameters

Product name: Emergency switch

Product model:LAY38K series

Heating current:10A

Rated voltage:660V

Contact form:1NO/1NC

Contact material: copper silver plated

Hole size:22mm

Button form: the lock


Product Detail

Product Tags

Zhejiang LVBO button manufacturing co.,ltd specialize in the production of emergency stop buttons. The emergency stop button can also be called the “emergency stop button”, as the name implies: when an emergency occurs, people can quickly press this button to achieve protection measures. At present, the machinery and equipment do not intelligently detect the surrounding environment and its own operating status at any time, and it is still necessary for on-site operators to photograph the emergency stop button at the emergency time to avoid major personal and property losses, but the emergency stop button will have the following misunderstandings during use:

1. Some sites will use the normally open point of the emergency stop button and then through PLC or relay to achieve the purpose of emergency stop, this wiring method once the emergency stop button contact is damaged or the control loop is broken, it can not be cut off immediately.

The correct approach should be to connect the normally closed point of the emergency stop button to the control loop or main loop, and quickly stop the output from the actuator at the moment the emergency stop button is taken.

2.The emergency stop button is only used in the event of an accident in operation, and some maintenance personnel press the emergency stop button to carry out maintenance work, in this case, once the emergency stop button is damaged or other personnel unknowingly reset the emergency stop button, it may cause significant losses to people and property.

The correct approach should be to list the power outage and detect the lack of power and carry out maintenance work.

3.Some sites, especially those with low frequency of use of the emergency stop button, may ignore the regular inspection of the emergency stop button, once the emergency stop button is blocked by dust or failure and is not found in time, it may not be able to cut off the danger in time when the fault occurs, resulting in major losses.

The correct practice is to check the E-STOP button regularly to avoid surprises.

Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply5 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply6 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply7 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply8 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply9 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply10 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply11 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply12 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply13 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply14 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply15 Emergency Stop Push Button Switch 12V24V Latching High Current Power Supply16